Home
Australia's Manufacturing and Industrial Directory
Add My Business - FREE
Newsletter Sign Up
Search
Ferret Categories
  • Automation, Process and Control
  • Computers and Software
  • Electronics and Components
  • Environment and Waste Management
  • Food and Beverage Processing
  • Health and Safety
  • Heavy Machinery and Equipment
  • Industrial Consumables
  • Industry Services
  • Materials Handling and Storage
  • Metal Working
  • Mining
  • Packaging, Labelling and Barcoding
  • Test and Measurement
  • Transport & Logistics
Ferret Newsletter

Be the first to know about new products, services and developments. Sign up for Ferret's Daily Product News.

invalid email address
Sign up
 

Access hundreds of Manufacturing and Operations jobs online!

Micro GC refinery and natural gas analyser available from Particle Test

Sections: Measurement Solutions | Internal Vacuum Pump | Measurement Equipment |
View All 13 Sections
By Particle Test
Email Particle Test Printable Version


Micro GC refinery and natural gas analyser
The Micro GC refinery and natural gas analyser from Particle Test combines micro-machined injectors and detectors, and high resolution capillary columns into a compact, modular gas chromatgraph.

Got a Question for Particle Test?
Enquire Now
Visit Website
Particle Test
Tel: 02 4304 1088
Fax: 02 4392 4368
15 Holly Cls
Lake Haven
NSW 2263
Visit Website Enquire Now
Update these details
Close

It analyses the individual components in sample gas and provides detailed reports of properties including composition, calorific value and density up to 10 times faster than a conventional GC system.

The hardware combined with Data System software and LAN interfacing, provides a powerful system complete with calorific value BTU or Mega Joule/m3) calculations and reporting according to GPA, ASTM and ISO standards.

There is no need to change the detector range to compensate for wide fluctuations in component concentration normally present in gas samples of various sources and types. Analysis of pressurised liquid samples, which are gases under standard temperature and pressure, is possible using optional sample conditioners.

Refinery gas analyser
Refinery gas samples are delivered to the sample inlet of the GC after passing through a sample conditioning system, which selectively removes any liquid fractions and particulate matter from the sample. This ensures that only gas phase sample is delivered to the RGA.

An internal vacuum pump draws this conditioned sample into each channel’s micro injector, when then injects the mixture onto each of the capillary columns for analysis. A complete analysis of hydrogen, saturated and olefinic hydrocarbons (C1-C5, and C6+ grouped peaks), plus fixed gases (O2, N2, CO, and CO2) is performed. Precise retention times and component areas translate into accurate component identification and quantification of the individual components present in refinery gas.

Four chromatographic modules are optimised and integrated to quickly separate and measure the individual components in refinery gas. Critical performance parameters such as sample volume, temperature and carrier gas pressure are precisely controlled to produce accurate and reliable measurements independent of ambient temperature and pressure. Vaporisation for gas introduction into the analyser.

Natural gas analyser
This analyser is applicable to natural gas samples from wellhead to pipeline-quality gas and Liquefied Petroleum Gas (LPG). Additionally, the analyser can handle Y-Grade Liquefied Natural Gas (LNG). Samples are easily introduced using sample cylinders, Tedlar bags or by direct connection to the pipeline or wellhead sampling points.

Two chromatographic modules are optimised and integrated to quickly separate and measure the individual components in natural gas. The analyser quickly separates and measures the permanent gases and hydrocarbons present using an optimised, dual-channel portable gas chromatograph.

This powerful, yet easy-to-use configuration is equally applicable to a wide range of sample types including pipeline gas, wellhead gas, LPG and Y-grade liquefied natural gas. Wellhead samples, or samples taken directly from the gas well, often contain significant amounts of hydrogen sulfide, yet there are no interferences and H2S can be measured from 50 PPM to 30 mol%. The portable GC uses digital signal processing with an expanded dynamic range.

For analysis of LPG, a heated vaporiser provides the backpressure necessary to ensure representative sampling and vaporisation for gas introduction into the analyser. For Y-Grade LNG, a de-methanised natural gas liquid under pressure which contains significant amounts of C6 plus material, an optional heated vaporiser interface is used to maintain sample integrity and provide the heat necessary.

20/11/2008 12:00 AM
More information about this product | Send to a friend |
Printable Version
Close Button Contact Particle Test
First Name
Last Name
Company Name
Contact Number
Email Address
Your State
Your Message

Please check this box if you want to receive the latest product updates in Ferret Daily Product News, Ferret's daily eNewsletter.

Get new security code
does not match
Send Enquiry

Your contact details will be passed onto this company (see our Privacy Policy)

More products from Particle Test

 
Particle Counter from Particle Test
Offers the highest resolution ensuring accuracy and precision Available in a laboratory, portable, online and robotic batch sampler A range of specially designed particle counters for every application and industry ...
More Info
Enquire Now
 
Patch Test Kit – Contamination Control from Particle Test
The Patch Test Kit is a valuable tool for the visual analysis of contamination levels and contaminate across a range of industries. The Patch Test Kit is currently being used in:  Contamination control programs ...
More Info
Enquire Now
News sign up

Related Articles

 
FLIR Systems announces introduction of second generation GF-Series Infrared Cameras (30/06/2009)
FLIR has released its second generation line of GF-Series infrared cameras, previously known as GasFindIR.
 
Digital, double-digital and analogue: sensor solutions for position detection in pneumatic cylinders (29/06/2009)
The target markets of magnetic cylinder sensors include the pneumatics industry, producers of material handling systems, the electronics industry, the packaging industry, as well as general and special machine constructo
 
New compact LaserGas oxygen analyser for hazardous areas (29/06/2009)
Anri Instruments & Controls is pleased to announce the launch of Neo Monitors AS new Tunable Diode Laser (TDL) model LaserGas 111 Single Path (SP) for Oxygen (O2), its 3rd generation of LaserGas analysers.
 
Package Integrity Tester (24/06/2009)
Bestech Australia presents the TSE6086 Package Integrity Tester, from Seal Tick, designed and developed to enable the testing of seals in food and pharmaceutical packages.
 
High-Speed Laser Profile Sensors from Bestech Australia (19/06/2009)
Bestech Australia Pty Ltd supplies laser profile sensors in Australia and New Zealand. Their laser profile sensors incorporate triangulation principle and are used for measurements on beads or grooves.
RSS Feed |
News sign up

Home | Add My Business | Submit Free Article | Advertise On Ferret | eNewsletter | News Archive
About Us | Contact Us | Careers | Privacy Policy | Terms Of Use | Helpful Links

Product/Service: # A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Companies: # A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Copyright © Reed Business Information (2.0.3-fsb). All material on this site is subject to copyright. All rights reserved.
No part of this material may be reproduced, translated, transmitted, framed or stored in a retrieval system
for public or private use without the written permission of the publisher.