Home > Martini bench meters

Martini bench meters

Supplier News

Mi160 pH/ORP/ISE/temperature laboratory bench meter

This new pH/ORP/ISE/temperature bench meter is ideal for very accurate and precise measurements for all laboratory needs. It can perform ion-selective measurements directly in ppm, as well as pH, ORP and temperature measurements. pH calibration can also be performed in three points selectable between seven memorised buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found. Thanks to the memory it can store up to 50 data sets for each range that can be downloaded to a PC.

· Seven memorised buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) for pH calibration

· pH calibration up to three points

· ISE calibration up to two points; six standard solutions available: 0.01, 0.1, 1, 10, 100, 1000 ppm

· Messages on the LCD to make the calibration easy and accurate

· Relative mV feature

· GLP feature, to view last calibration data for pH or ISE

Mi170 Autoranging EC/TDS/NaCl/temperature laboratory bench meter

Mi170 measures four different parameters – EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.

The autoranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25OC and the compensation coefficient is selectable by the user.

The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy.

Conductivity readings are performed with the four-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status. It is also PC compatible.

Mi190 Extended range bench dissolved oxygen meter

Ideal for testing dissolved oxygen in the pharmaceutical and food industry, as well as monitoring in water treatment plants. The user can choose to measure DO readings in mg/L of O2 or percentage of saturation.

This meter can be used for any type of water, as it allows measurements to compensate for temperature, altitude and salinity factors. The automatic logging interval can be set to perform analysis and store data into the memory.

All logged data can be downloaded to a PC. Memory can store up to 50 samples. Mi190 features an automatic calibration procedure, at one or two points (at 0 and 100 per cent of O2 saturation). The polarographic probe supplied with the meter (MA842/2) measures the current generated by the reaction of O2 with Ag.

Also available from Milwaukee Meters are the Mi150 pH/temperature laboratory bench meter and the Mi151 pH.ORP/temerature laboratory bench meter.

Newsletter sign-up

The latest products and news delivered to your inbox