Home > The James IQM fresh concrete aging testing system from Hylec Controls

The James IQM fresh concrete aging testing system from Hylec Controls

Supplier News
article image The James IQM fresh concrete aging testing system from Hylec Controls
logo
02 96454777

Contact supplier

Your Email * indicates mandatory fields.
image

The IQM from Hylec Controls enables fresh concrete to be easily and completely monitored in the field for improved safety, quality assurance and optimum setting time. Designed specifically for monitoring and analyzing fresh concrete, the IQM concrete testing system module is programmed with the required equivalent age of the concrete under test. Once this preset maturity number is reached, a visual indicator will flash continuously, providing an effective, automatic indication that the concrete has reached the desired level of maturity.

Features of the concrete testing system includes:

  • Software and interface cable allow direct uploading of the data to a Windows PC environment where it can be imported into any spreadsheet, word processor or graphing program for further analysis
  • Temperature history on the concrete testing system can be graphically displayed with respect to time
  • The IQM software will create maturity indices from the complex Arrhenius equation according to ASTM procedure
  • The strength gain can be calculated and all these parameters can be graphically displayed with respect to time
  • The James IQM concrete testing system enables fresh concrete to be easily and completely monitored in the field for improved safety, quality and optimum stripping time
  • Its modular design facilitates number and choice of monitoring locations
Specifications of the concrete testing system are:
  • Battery type: 1-9 V Battery
  • Recording temperature range: –20—100°C
  • Model M-IQM-4010: K-Thermocouple Module  
  • Weight of the concrete testing system: 10 oz (280 grams)
  • Operating system: Windows 9x / ME or later
  • Ram: 32 MB HARD DISK SPACE: 8 MB
  • Memory size: >8000 Data Points
  • Interval between readings:  From 1 Min. to 24 hrs. in Minute increments
  • Memory type: Non-Volatile
  • Model M-IQM-4011: 3 ft (1 m) “K”Thermocouple  
  • Battery type: @20°C: 30 Days recording every 30 Minutes
  • Model M-IQM-4040: Software to calculate maturity & strength
  • Prpcessor: 166 MHz Pentium or faster
  • Dimensions: 1.5 x 2.5 x 5 inches (38mm x 63 x 127mm)  
     

Newsletter sign-up