Pressure sensor monitoring kit

Supplier News
article image SDE 1 pressure switches and pressure sensors.
1300 889696

Contact supplier

Your Email * indicates mandatory fields.

PRESSURE drops and fluctuations have an immediate negative effect on productivity. With the pressure sensors and pressure switches in the SDE 1 kit from Festo , all the current pressure values - including minimum and maximum pressure values - are continually monitored.

The SDE 1 is a complete, cost-effective kit for pressure measurement, pressure monitoring and pressure queries. In addition to monitoring the air mains connection, other important SDE 1 application sectors include monitoring a service unit, vacuum applications, leak tests and testing and controlling a pre-defined working pressure.

The clear and well laid-out display combines all the important requirements: simple commissioning, very user-friendly guidance for installation, well lit information regarding status, and display of all the values required during operation.

An individual and cost-effective selection is offered: from a wide variety of features such as two pressure variants, four connection variants, two display variants, PNP or NPN output, and the assembly variants such as external thread, top-hat rail or wall assembly.

And a further plus thanks to the kit principle, customers only pay for the functions they require.

The pricing of the SDE1 makes it extremely affordable. Thanks to the intelligent multifunctional modular system, the cost is around that of mechanical pressure switches.

The SDE1 is extremely simple to install. It takes about 10% of the time required for conventional switches. Commissioning times are also drastically reduced as a result of the SDE1's unique "learning mode", particularly as the display clearly shows intuitive symbols.

In addition to the many combination options, the switching behaviour of the digital outputs can be defined. In the case of the threshold value signal, an electrical output signal is set once the specified switching point has been reached.

In the case of the window comparator signal, the output signal is only set or reset within a specified pressure range.

The pressure sensor switching points can also be defined via the double teach-in system. They are specified when the pressure is applied. Manual input via the display is also available.

To protect the plant and workforce, a code can be used to secure the SDE 1 against unauthorised changes.