New range of transmitters available from AMS Instrumentation & Calibration (8-Sep-2008)
AMS Instrumentation & Calibration offer a new range of transmitters.
FLUID Components, represented in Australia by AMS Technical Services , has released the FlexMASSter ST98B-CA thermal mass flowmeter. It is factory precalibrated for rapid delivery and installation.

Flowmeters installed on compressors and air lines measure air flow, allowing operators to optimise process air flow rates and detect leaks. With air consumption data available, plant maintenance staff can quickly identify leaks, locate their potential sources and determine whether repair or overhaul of equipment is necessary. A single air line with a 3mm hole will leak at rate of 260Nm3/h, which can result in an energy cost of $6000 or more a year.
In large plants batteries of compressors can be analysed during peak and off-peak time usage. Controllers can then run the most efficient compressors at certain loads based on the feedback provided by the flowmeter. This allows a more efficient plant and a longer life span for compressors.
Flow detection capability ranges from 1.8smps to 180smps in air or nitrogen. Inputting the pipe ID allows the system to provide selectable mass flow units such as scfm, lbs/h and Nm3/h. Accuracy is +1% of reading +0.5% full scale, with a repeatability of +0.5% of reading.
The 4mA-20mA output is range adjustable from a 10:1 to 100:1 turndown. Voltage output is also available and selectable in 0V dc to 10V dc, 0V dc to 5V dc, or 1V dc to 5V dc. The package design allows easy access to the termination points and communication ports. The flowmeter comes in integral and remote configurations. It is supplied in a weather-resistant NEMA 4X enclosure rated for Division 2 areas. An RS-232C serial port interfaces with FCI's optional FC88 Communicator, a computer, or any ASCII terminal.
The ST98B-CA's sensing element is made up of two all-welded 316 stainless steel thermowells that protect its platinum resistance temperature detectors (RTDs). One RTD is heated relative to the reference RTD and the temperature difference between the two is related to the process mass flow rate. The standard flow elements have adjustable insertion lengths of 25mm to 300mm. The process connection is a three-quarter inch male NPT with a Teflon ferrule rated to 10 bar (g) and 93°C.
30-Jun-2004
New range of transmitters available from AMS Instrumentation & Calibration (8-Sep-2008)
NOSHOK 800 series of indicating pressure switches from AMS Instrumentation & Calibration (29-Aug-2008)
Model ST51 Mass Flow Meter for digester gas flow measurement from AMS Instrumentation & Calibration (6-Aug-2008)
Model ST51 Mass Flow Meter from AMS Instrumentation & Calibration (5-Aug-2008)
ABB launch HygienicMaster range of flow meters (2-Sep-2008)
Resolvers for sensing rotary position from Balmoral Technologies (1-Sep-2008)
ABB Australia’s power solution for Incitec Pivot’s ammonium nitrate plant (29-Aug-2008)
Enhanced communications for EZ touch screens and panels from Balmoral Technologies (19-Aug-2008)
Access over 2000 Manufacturing and Operations jobs online!
Ronan Engineering Ronan Engineering has enjoyed continuous growth over the years as a result of innovative management dedicated to the fulfillment ...
ST98 Flow Meter The ST98 Flow Meter sets the industry standard for performance and value with a reliable thermal mass flow sensor in a smart electronics ...
Yamatake Since its founding in 1906, Yamatake has built on its core of measurement and control technologies to maintain its position at the forefront ...
Computer-aided calibration management is becoming more and more common for managing calibration information and calibration assets in the process industry. ...